Post
This document assumes competence on the part of the reader in terms of amplifier systems, electronic components, and good electronic safety and working practices.Get more news about Amplifier Front Panel,you can vist our website!
Safety First
Throughout this document, special emphasis is placed on good safety practices. The safety graphics provided here are used to highlight certain topics which require extra precaution.
Summary
These instructions describe the process for removing and replacing the top cover of a 7548 or 2110 amplifier.
Tools Required
T-15 Torx driver
1/8-inch Hex Key driver
5/32-inch Hex Key driver
Procedure
Remove power from the amplifier and disconnect any load from the amplifier outputs. Wait a minimum of three minutes to allow the amplifier's capacitors to discharge.
Remove front panel:
Use the 1/8-inch hex key driver to remove the four (4) button head hex screws from the front panel, as shown in Figure 1.
Pull the panel towards you to remove.